Home / InstaClean
Electrical and electronic panel cleaning
Clean live electrical panels without a shutdown
InstaClean is a 100% non-conductive liquid that is sprayed onto electrical and electronic components to remove dust, moisture and oil films, in Power ON or Power OFF mode.

The problem
Dust is the quiet cause of electrical failures
In the Gulf's dusty, humid conditions, panels collect a layer of dust that mixes with moisture and oil vapour. That layer acts as insulation, traps heat and creates paths for tracking.
- Overheating, sparks, arcing and corona effect
- Static electricity and short circuits
- Electrical noise that causes communication errors
- Premature, unexpected equipment failure
- Fire risk and costly repairs and replacements
Why liquid cleaning
Compressed air moves dust. InstaClean removes it.
| Traditional compressed air | InstaClean liquid spray | |
|---|---|---|
| Dust | Scatters in all directions and settles elsewhere | Falls to the bottom of the panel with the liquid, with no scattering |
| Sticky deposits | Thick or sticky deposits cannot be removed | Lifted quickly, even from the deepest points |
| Oil films | Oil stains and micro-oil films stay on | Fine oil deposits are removed |
| Moisture | Moisture inside components stays in | Flushed out and evaporates |
| Shutdown | Full power shutdown required | Shutdown is not mandatory |
The method
Liquid spray cleaning in four steps
Spray
Liquid and compressed air are sprayed onto components to remove dust, moisture and micro-oil films.
Brush
Heavy deposits are loosened with a non-conductive nylon-bristle brush.
Air dry
Compressed air dries the cleaning liquid quickly, leaving no residue.
Collect
Dirt falls with the liquid and is collected at the bottom of the panel.
Controlled pressure. Spray pressure is pre-set below 0.5 kg at the outlet, so no cable or wire connection is disturbed. The process is manual and follows mandatory standard operating procedures for every panel.
Results
Before and after
Photographs from real cleaning jobs. After spray cleaning, an anti-corrosive layer forms on the component surface.
BEFORE
AFTERVariable frequency drives
Cleaned externally while running, with zero minutes of shutdown. A complete Power OFF clean, including circuit boards, takes about 15 minutes.
BEFORE
AFTERContactors and control gear
Dust and deposits are flushed off contactors, relays and wiring and collected at the bottom of the panel.
Cooler components, measured
Infrared readings taken before and after cleaning show lower surface temperatures once the insulating dust layer is gone.
| Equipment | Before | After | Change |
|---|---|---|---|
| Heat pump starter panel incomer | 34.1 °C | 31.2 °C | −2.9 °C |
| Electrical panel | 98.8 °F | 92.8 °F | −6.0 °F |
Benefits to your operation
- Dust-free electrical and electronic components
- Lower heat losses and component temperature
- Fewer component failures and longer equipment life
- Lower annual maintenance and repair costs
- Works on no-break equipment with no shutdown
- Better protection against fire and accidents
See it in action
Live cleaning on site
Product
Two grades of cleaning liquid
Both are 100% electrically non-conductive, non-corrosive to metals and leave no residue after drying.
| NWK 99 OPP · standard grade | NWK 99 · for critical equipment | |
|---|---|---|
| Best suited for | All electrical and electronic components; panels up to 33 kV and control panels | UPS, data centres, and equipment in mines, tunnels and other poorly ventilated or underground installations up to 33 kV |
| Flammability | Has a flash point; safe with proper precautions | No flash point (non-flammable) |
| Evaporation | 30–40 minutes naturally; about 5 minutes with an air blower | About 30 seconds naturally |
| Consumption | Lower consumption, larger area cleaned | Higher consumption, smaller area cleaned |
| Packaging | 15.3 kg container | 20 kg container |
| Shelf life (sealed) | 25 years | 3 years |
Auto-ignition temperature 332 °C. Store in a cool, dry place away from water and fire. Use as supplied and never dilute. Safety data sheets are available on request.
Applications
One method for a wide range of equipment
- HT and LT panels
- VFDs and inverters
- UPS and server rooms
- Data centres
- CNC machine panels
- Overhead crane panels
- Conveyor belt panels
- Wind turbine panels
- EV charging stations
- Railway and metro panels
- Earth mover panels
- ATM machine panels
- Batteries and gensets
- Electric motors
- Electronic circuit boards
Safety
Live work, done properly
Cleaning energised equipment demands discipline. These checks and rules are mandatory on every job.
Checks before Power ON cleaning
- Contamination level inside the panel, with photos
- Loose terminations and any sparking or arcing
- Condition of relays, wires, contactors and displays
- Surface temperature of components at several points
- Hot spots, using a thermal camera
- Insulation resistance readings
Checks are carried out with the end user present, and recorded.
Rules on site
- Work starts only with permission from the site safety team
- Rated PPE: gloves, helmet, eye protection, mask, safety shoes
- Only OEM-supplied spray guns and accessories
- The liquid is never diluted or mixed with additives
- Adequate ventilation in enclosed spaces
- Work stops immediately if any abnormality occurs
Cleaning is carried out by trained technicians following the operating manual.
Where we work
Panel cleaning across the Emirates
Local conditions, areas covered and typical sites for each emirate.
See InstaClean in action at your site
We will clean a live panel and show you the before and after, including temperature readings.